Specifications |
|
Model |
SUN-5K-SG06LP1-EU-BM2 |
|
Battery Input Data |
|
Battery Type |
Lead-acid or Lithium-ion |
|
Battery Voltage Range(V) |
40-60 |
|
Max.Charging/Discharging Current(A) |
120 |
|
Charging Strategy for Li-ion Battery |
Self-adaption to BMS |
|
Number of Battery Input |
1 |
|
PV String Input Data |
|
Max. PV Access Power (W) |
10000 |
|
Max. PV Input Power(W) |
8000 |
|
Max. PV Input Voltage(V) |
500 |
|
Start-up Voltage(V) |
125 |
|
MPPT Voltage Range(V) |
150-425 |
|
Rated PV Input Voltage(V) |
370 |
|
Max. Operating PV Input Current(A) |
18+18 |
|
Max. Input Short-Circuit Current(A) |
27+27 |
|
No.of MPP Trackers/No.of Strings MPP Tracker |
2/1+1 |
|
AC Input/Output Data |
|
Rated AC Input/Output Active Power(W) |
5000 |
|
Max. AC Input/Output Apparent Power (VA) |
5500 |
|
Rated AC Input/Output Current(A) |
22.8/21.8 |
|
Max. AC Input/Output Current(A) |
25.0/24.0 |
|
Max. Continuous AC Passthrough (grid to load)(A) |
50 |
|
Peak Power (off-grid)(W) |
2 times of rated power,10s |
|
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
|
Rated Input/Output Voltage |
220V/230V 0.85Un-1.1Un L+N+PE |
|
Rated Input/Output Grid Frequency/Range(Hz) |
50/45-55, 60/55-65 |
|
Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
|
DC Injection Current |
<0.5%ln |
|
Efficiency |
|
Max. Efficiency |
97.6% |
|
Euro Efficiency |
96.5% |
|
MPPT Efficiency |
>99% |
|
Equipment Protection |
|
Integrated |
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection,
AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (AFCI) (optional),
Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
|
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
|
Interface |
|
LCD/LED Display |
LCD |
|
Communication Interface |
WIFI, RS485, CAN |
|
General Data |
|
Operating Temperature Range (℃) |
-40 to +60℃,>45℃ Derating |
|
Permissible Ambient Humidity |
0~100% |
|
Permissible Altitude |
3000m |
|
Noise(dB) |
<45 |
|
Ingress Protection(IP) Rating |
IP 65 |
|
Inverter Topology |
Non-Isolated (solar), Isolated (battery) |
|
Over Voltage Category |
OVC II(DC),OVC III(AC) |
|
Cabinet size(W*H*D mm) |
310×460×218 (Excluding Connectors and Brackets) |
|
Weight(kg) |
15.6 |
|
Type Of Cooling |
Natural Cooling |
|
Warranty |
5 Years / Up to 10 Years* *Warranty period varies by installation country. Refer to the Warranty Policy for details. |
|
Grid Regulation |
IEC 61727,IEC 62116,CEI 0-21,EN 50549, NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
|
Safety/EMC Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |